T9000 220/380V 1/3 Phase Open/Closed Loop Vector Control AC Variable Frequency Drive Variable Speed Drive

ZONCN

1.Open loop/closed loop vector control, V/F control (built-in PID) of synchronous and asynchronous motors 2.Large torque output, which can ensure smooth starting of motor under heavy load 3.Support PG cards, instant stop and instant start 5. Power range: 220V:0.4-3.7kW 380V:0.4-450kW

Details

T9000   Series

Advanced Vector Control Inverter

· Open loop/closed loop vector control, V/F control (built-in PID) of synchronous and asynchronous motors

· Large torque output, which can ensure smooth starting of motor under heavy load

· Powerful function and outstanding  performance, suitable for most general occasions

· Support multiple types of PG cards

· Support instant stop and instant start

· Compact structure, easy to install

· Power range: 220V:0.4-3.7kW  380V:0.4-450kW


Technical Specification

Item

Description

Basic function

Control Mode

VF control

Sensorless flux vector control(SVC)

Close-loop vector control(FVC)(Above 3.7kW)

Maximum frequency

0~600Hz

 Carrier frequency

0.5kHZ——8kHz

The carrier frequency is automatically adjusted based on the load features

Input frequency resolution

Digital setting:0.01Hz

Analog setting: Maximum frequency x 0.025%

 Start torque

G Type:0.5Hz/150%(SVC)

P Type:0.5Hz/100%

Speed range

1:100 (SVC)

Speed stability accuracy

±0.5%(SVC)

 Overload capacity

G Type:60s for 150% of the rated current, 3s for 180% of the rated current.  

 P Type:60s for 120% of the rated current, 3s for 150% of the rated current.

Torque boost

Auto-boost ;

Customized boost: 0.1%~30.0%

 V/F Curve

Straight-line V/F curve

 Multi-point V/F curve

 N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square)

V/F separation

2 types: complete separation; half separation

Ramp Mode

Straight-line ramp.

Four groups of acceleration/deceleration time with the range of 0.00`6500.0s

 DC braking

DC braking frequency:0.00Hz~Maximum frequency

Braking time:0.0s~36.0s

Braking action current value:0.0%~100.0%

JOG control

JOG frequency range:0.00Hz~50.00Hz

JOG acceleration/deceleration time: 0.0s~6500.0s。

Simple PLC, Multiple preset speeds

It implements up to 16 speeds via the simple PLC function or combination of terminal states

Onboard PID

It realizes process-controlled closed loop control system easily

Auto voltage regulation (AVR)

It can keep constant output voltage automatically when the mains voltage

Overvoltage/overcurrent stall control

The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over voltage/over current

Rapid current limit

It helps to avoid frequent over current faults of the AC drive.

 Torque limit and control

It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be

implemented in the FVC mode.

 

Support for multiple PG card

Support for differential input PG card, resolver PG card ,rotating transformer PG card

Basic function

Simple PLC,Multiple preset

It implements up to 16 speeds via the simple PLC function or combination of terminal speeds states

Onboard PID

It realizes process-controlled closed loop control system easily

Auto voltage  regulation(AVR)

It can keep constant output voltage automatically when the mains voltage changes

Overvoltage/overcurrent stall control

The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over voltage/over current

Rapid current limit

It helps to avoid frequent over current faults of the AC drive.

Torque limit and control

It can limit the torque automatically and prevent frequent over current tripping during the running process.Torque control can be implemented in the FVC mode.

Individualized function

High performance

Control of asynchronous motor are implemented through the high-performance current vector control technology

Rapid dip ride through

The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time

Support multiple PG card

Support for differential input PG card, resolver PG card, rotating transformer PG card...

Rapid current limit

It helps to avoid frequent over current faults of the AC drive.

Timing control

Timing range:0.0Min~6500.0Min

Communication methods

RS-485

Running

Command source

Operation panel/Control terminals/Serial communication port. You can perform switchover between these sources in various ways.

Frequency source

There are ten frequency sources. Digital setting, analog voltage setting, analog current setting, pulse setting, serial port setting. You can perform switchover in various ways.

Auxiliary frequency source

There are ten auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis.

Input terminal

Standard:4 digital input terminals(Below 5.5KW)/6 digital input terminals(Above 7.5KW);  1 analog input terminal(Below 5.5KW)/2 analog input terminals(Above 7.5KW);  1 voltage input(only support for 0~10V,above 7.5KW),1 voltage input(0~10V)or current input(4~20mA)

Output terminal

1 High-speed pulse output terminal(Open-collector)(Above 3.7KW)

1 replay output terminal(Below 5.5KW/2 replay output terminals(Above 7.5KW)

1 analog output terminal(3.7KW~5.5KW)/2 analog output terminal(Above 7.5KW), Support for 4~20mA current output or 0~10V voltage output

Display and operation panel

LED display

It displays the parameters

Key locking and function selection

It can lock the keys partially or completely and define the function range of some keys so as to prevent mal-function.

Protection mode

Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, over voltage protection, under voltage protection, overheat protection and overload protection

Environment

Installation location

Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.

Altitude

Lower than 1000m

Ambient temperature

 -10℃~+40℃(de-rated if the ambient temperature is between 40℃~50°℃)

Humidity

Less than 95%RH,without condensing

Vibration

Less than 5.9m/s2(0.6g)

Storage temperature

-20℃~+60℃


Specification

Model

Input Current

( A)

Output Power

(KW)

Output Current

(A)

Motor

( KW)

Input Voltage(V):1PHAC220V±15%

T9200-0R4G

5.4

0.4

2.1

0.4

T9200-0R75G

7.2

0.75

3.8

0.75

T9200-1R5G

10

1.5

7.2

1.5

T9200-2R2G

16

2.2

9

2.2

T9200-3R7G

17

3.7

17

3.7

Input Voltage(V):3PHAC380V±15%

T9400-0R4G

3.4

0.4

2

0.4

T9400-0R75G

3.8

0.75

2.5

0.75

T9400-1R5G

5

1.5

3.7

1.5

T9400-2R2G

5.8

2.2

5

2.2

T9400-3R7G/5R5P

10/15.0

3.7/5.5

9.0/13

3.7/5.5

T9400-5R5G

15

5.5

13

5.5

T9400-7R5G/11P

20/26

7.5/11

17/25

7,5/11

T9400-11G/15P

26/35

11/15.0

25/32

11/15.0

T9400-15G/18.5P

35/38

15/18.5

32/37

15/18.5

T9400-18.5G/22P

38/46

18.5/22

37/45

18.5/22

T9400-22G/30P

46/62

22/30

45/60

22/30

T9400-30G/37P

62/76

30/37

60/75

30/37

T9400-37G/45P

76/90

37/45

75/91

37/45

T9400-45G/55P

92/113

45/55

91/112

45/55

T9400-55G

113

55

112

55

T9400-75P

157

75

150

75

T9400-75G/90P

157/180

75/90

150/176

75/90

T9400-90G/110P

180/214

90/110

176/210

90/110

T9400-110G/132P

214/256

110/132

210/253

110/132

T9400-132G/160P

256/307

132/160

253/304

132/160

T9400-160G/185P

307/355

160/185

304/340

160/185

T9400-185G/200P

355/385

185/200

340/377

185/200

T9400-200G/220P

385/430

200/220

377/426

200/220

T9400-220G/250P

430/475

220/250

426/465

220/250

T9400-250G/280P

475/525

250/280

465/520

250/280

T9400-280G/315P

525/610

280/315

520/585

280/315

T9400-315G/350P

610/665

315/350

585/650

315/350

T9400-350G/400P

665/730

350/400

650/725

350/400

T9400-400G/450P

730/830

400/450

725/820

400/450

T9400-450G/500P

830/885

450/500

820/880

450/500

Wiring Diagram

1.1PH/220V 0.4-2.2KW &3PH/380V 0.4-2.2kW(VF control)


Note: It is only for V/F control

2.1PH/220V 0.4-3.7KW&3PH/380V 0.4-5.5KW(vector control)


Note: Terminals B1 and B2 are only available for products above 220V/2.2kW & 380V/3.7kW.

3.380V 7.5KW-450kW


Note: It is built-in braking unit for 3.7-37kW,the braking unit is optional for 45-450kW



Get an offer or Book a Service

Get an offer or Book a Service

Mobile:
+86 17730128805
WhatsAPP:
+8617730128805
Tel:
+86-553-2619975
WeChat:
+8617730128805
E-Mail:
sales@vinac.cn
info@vinac.cn
Address: